UniViewAsk about services, support or a quote.

Photo 1 of 2
| Brand | Unbranded |
|---|---|
| Category | Power & Charging / Inverterë |
AC Input
Phase & waveform
Single phase & Pure Sine Wave
Voltage
110/120/130VAC or 220/230/240VAC
Acceptable Voltage
95-126VAC or 194-253VAC±4%
Low Line Disconnect
85VAC±4% or 184VAC±4%
Low Line Re-connect
95VAC±4% or 194VAC±4%
High Line Disconnect
136VAC±4% or 263VAC±4%
High Line Re-connect
126VAC±4% or 253VAC±4%
Frequency
50Hz:41-54Hz 60Hz:51-64Hz
AC Output
Phase & waveform
Single phase & Pure Sine Wave (bypass mode sync to input)
Voltage
110/120/130VAC or 220/230/240VAC±10%rms (bypass mode sync to input)
Frequency
50Hz±0.3Hz 60Hz±0.3Hz (bypass mode sync to input)
Peak Power
3 times of rating power
Short Circuit Protection
Yes, shutdown after 10ms
Power Factor
0.9-1.0
DC Input
Battery Voltage
12VDC or 24VDC
Minimum Start Voltage
10VDC or 20VDC
Low Battery Alarm
10.5±0.3vdc or 21±0.6vdc
Low DC input Shutdown
10±0.3vdc or 20±0.6vdc
High DC input Alarm & Fault
16±0.3vdc or 32±0.6vdc
High DC input Recovery
15.5±0.3vdc or 31±0.6vdc
MAX Charger Current
20A/35A (According to the Inverter model)
System parameter
Battery Mode Efficiency
>85%
Line Mode Efficiency
>96%
Power saver
Load <=25W (Enabled on “P/S auto” setting of Remote control)
Audible Alarm
Sounding when the heat sink’s tem is over 100℃ and shutdown after 30 seconds.
Overload Protection
110% Load>150%, beeps 0.5s every 1s, and Fault after 20s.
Protections
low battery、over charging、over temp、over load
Communications
RS-232/USB/SNMP (custom-made)
Operating Environment
0-40℃,0-90%RH (non-condensing)
Audible Noise
<60dB
For businesses, partners and installers: tell us the quantity and project needs. Our team will contact you with a quote.